Cluff Industries is also an expert in designing and building Clean Rooms.

SERVICES

Biological safety cabinets

image6

Testing & Certification

Primary Testing

· Inflow velocity measurements 

· Down-flow velocity measurements –

· HEPA filter Leakage testing 

· Smoke pattern testing 

· Site installation testing and alarm calibration 

Optional Secondary Testing

· Non-viable particle counting – performed in accordance with ISO 14644-1 

· Electrical safety testing 

· Fluorescent light testing 

· UV light testing –

· Vibration testing –

· Sound testing – 


  All testing performed by a qualified Licensed NSF Accredited Bio-Safety Cabinet Field Certifier 

Biological Safety Cabinet

image7

Testing & Certification

  

  • Chlorine Dioxide Gas Decontaminations
  • Removal and Disposal of older BSC Cabinets from your site
  • Installation of New BSC’s including seismic strapping
  • Ducting to dedicated exhaust systems
  • Complete Repairs including, blowers, motors, electrical components, glass sash cables, glass replacement etc

Chemical Fume Hoods

image8

Testing & Certification  


  • OSHA, AIHA, SEFA, NEBB Standards
  • Velocity Profile Tests 
  • Smoke Containment Testing
  • ASHRAE 110 Testing – Nitrous Oxide Tracer Gas
  • CCR Title 8 5154.1 Testing
  • Air Flow Alarms , Installed and      Calibration
  • Ductless Fume hood Testing and      certifications
  • Slot Vents, Canopy’s, and Fume Arms      Testing and certification per AIHA
  • VAV , CV , Ductless and Auxiliary Fume Hoods Tested

Clean Rooms/ Clean Benches

image9

Testing & Certification

   

  • Non Viable particle count testing per ISo 14644-1 Cleanliness Standards
  • Viable Air Sampling for Fungi and Bacteria
  • Viable Surface Sampling for Fungi and      Bacteria 
  • AIHA Accredited Analytical Lab
  • HEPA filter Leakage / Integrity Testing
  • CFM / Air Volume Measurements
  • Air balancing
  • Air Changes per Hour ( ACPH) calculations
  • Pressurization , Room pressure      differential measurements
  • Sound Testing
  • Vibration testing
  • Dry Ice Air Flow Patterns
  • Room Recovery testing

Laminar Air Flow Workstations

image10

Testing & Certification


  

  • Non Viable Particle Count Testing per ISO 14644-1 Cleanliness Standards
  • Velocity Profile Tests 
  • Smoke Visual tests
  • HEPA filter Leakage Testing
  • Lighting Tests
  • Sound Testing
  • Vibration testing



BSL-3 Laboratories

image11

Testing & Certification


  

  • HEPA filter Leakage / Integrity Testing
  • CFM / Air Volume Measurements
  • Air balancing
  • Air Changes per Hour ( ACPH) calculations
  • Pressurization , Room pressure      differential measurements
  • Air Flow Alarm testing , calibration
  • Chlorine Dioxide Gas CIO2 Decontamination
  • Decommissioning 
  • Filter Replacements

Animal Research Vivariums

image12

Testing & Certification


  

  • Animal Rack Testing and Certification 
  • Animal Change Stations testing and      Certification
  • HEPA filter Leakage / Integrity Testing 
  • CFM / Air Volume Measurements on all Rooms      , Breeding Rooms, Procedure Rooms , Quarantine
  • Air Changes per Hour ( ACPH) calculations
  • Pressurization , Room pressure      differential measurements
  • Air Flow Alarm testing , calibration
  • Chlorine Dioxide Gas CIO2 Decontamination 
  • Actril / Hydrogen Peroxide H2O2 Room      Fogging and Decontamination
  • Decommissioning 
  • Filter Replacements

Additional Services

Pharmacies

image13

  • Chemo Hoods (Semi-Annual Certification)
  • IV Hoods  (Semi-Annual Certification)
  • Particle Counts in Clean Zones per ASHP 797
  • ISO 14644-1 Testing
  • Pre-filter and HEPA filter Service

Hospitals

image14

  • Biological Safety Cabinets (Testing and  Certification)
  • Chemical Fume Hoods (testing and Certification)
  • Chemical Exposure Monitoring (Formaldehyde, Xylenes,  Ethanol etc.)
  • Air Ventilation Studies

Chemical Exposure Monitoring

image15

  • Laminar Flow Walls and Surgery Isolators (Testing  per ISO 14644-1)
  • Particle Counts, CFM’s, FPM’s, HEPA filter Leakage  Test
  • Anesthetic Gas Monitoring (Halothane, Isoflurane,  Sevoflurane, Nitrous Oxide)
  • Ventilation Studies for All surgery Suites 
  • Central Sterilization Monitoring (Acetic Acid,  Gluteraldehyde)
  • Labor and Delivery rooms

Decontamination Services

image16

  • Pre-filter and HEPA filter service  
  • Air Changes per hour / CFM testing
  • Pressurization
  • Portable HEPA filter units for sale

Incubators

image17

  • Animal Rack testing
  • Air Balancing
  • Building Decontaminations
  • HEPA filter and pre-filter maintenance programs

Air Scrubbers / Negative Air Machines

image18

  • Clean Room Designs and Installations
  • Charcoal Filter systems
  • Fan Powered HEPA filter Ceiling Modules Installed
  • Clean Benches and Hoods Certified

IVF Laboratories

image19

  • Clean Room Designs and Installations
  • Charcoal Filter systems
  • Fan Powered HEPA filter Ceiling Modules Installed
  • Clean Benches and Hoods Certified

Microbial Testing / IAQ Services

image20

  • Air Sampling 
  • Surface Sampling
  • Mold Remediation 
  • Chemical Exposure Monitoring
  • AIHA accredited laboratory testing and analysis
  • Indoor Air Quality Study / Ventilation Study

More Information?

image21

For Additional Information please click on the button below

Find out more

Contact Us

Drop us a line!

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Better yet, see us in person!

We love our customers, so feel free to visit during normal business hours.

Cluff Industries

32158 Camino Capistrano A364, San Juan Capistrano, California 92675

(888) 502-5880

Hours

Mon

9:00 am – 5:00 pm

Tue

9:00 am – 5:00 pm

Wed

9:00 am – 5:00 pm

Thu

9:00 am – 5:00 pm

Fri

9:00 am – 5:00 pm

Sat

Closed

Sun